| Storage Capacities |
Minimum capacity |
8TB |
9TB |
9TB |
| Maximum capacity |
62TB |
720TB |
1080TB |
| Maximum number of drives in chassis |
15 |
0 |
0 |
| Maximum number of drives w/ expansion chassis |
31 |
240 |
360 |
| Minimum number of drives |
8 |
9 |
9 |
| Rack space required for 60 drives (U) |
N/A |
7 |
7 |
| Density (drives per U with no expansion chassis) |
5 |
13 |
13 |
| SATA or NL-SAS 7200RPM drives (TB) |
1/2 |
1/2/3 |
1/2/3 |
| SAS 15K RPM drives (GB) |
450/600 |
450/600 |
450/600 |
| SSD drives (GB) |
N/A |
100/200/400 |
100/200/400 |
| Mix drive types in chassis |
NO |
YES |
YES |
| Storage Controller |
Base / maximum controllers per system |
1/2 |
2/2 |
2/2 |
| Base / maximum number of CPU cores per controller |
4/4 |
4/8 |
12/12 |
| Base / maximum system memory per controller |
12/12 |
24/48 |
48/96 |
| RAID Levels |
5,6,10 |
5,6,10 |
5,6,10 |
| FASTier™ |
FASTier™ Package Contents |
(1) 100GB SLC SSD |
(1) 8GB DRAM / SSD & (2) 100GB SLC SSDs |
(1) 8GB DRAM in SSD & (3) 200GB SLC SSDs |
| Number of drive slots required for the FASTier™ Package |
1 |
3 |
4 |
| Maximum number of FASTier™ Packages per system |
1 |
3 |
4 |
| Maximum FASTier™ dedicated high speed flashbacked DRAM write cache in SSDs per system |
N/A |
24GB |
32GB |
| FASTier™ Expansion Package Contents |
N/A |
(2) 100GB SLC SSDs |
(2) 200GB SLC SSDs |
| Base / Maximum FASTier™ cache size |
0/100GB |
0/1.5TB |
0/3TB |
| I/O Ports |
Base / maximum 1Gb Ethernet ports per controller |
2/6 |
2/6 |
2/6 |
| Base / maximum 10Gb Ethernet ports per controller |
0/2 |
0/2 |
0/2 |
| Dedicated/available Ethernet management ports per controller |
0/2 |
0/2 |
0/2 |
| Link aggregation (IEEE 802.3ad) |
YES |
YES |
YES |
| Base / maximum # of SASx4 ports (24Gb each) for drive expansion per controller |
1 |
0 |
0 |
| Base / maximum # of 8Gb Fibre Channel ports for drive expansion per controller |
N/A |
2/4 |
2/6 |
| High Availability |
Dual Redundant storage controllers with automatic failover |
Opt. |
YES |
YES |
| No single point-of-failure architecture |
Opt. |
YES |
YES |
| Rails & Cables |
Mounting Rails and SAS / FC Cables Included |
YES |
YES |
YES |
| NAS Services Capacities |
Number of NAS heads in cluster base/maximum |
1/2 |
2/2 |
2/2 |
| Maximum file size (TB) |
16 |
16 |
16 |
| Maximum number of CIFS shares per controller |
512 |
512 |
512 |
| Maximum number of NFS shares per controller |
512 |
512 |
512 |
| Maximum file name length (bytes) |
255 |
255 |
255 |
| Maximum number of snapshots per share |
2048 |
2048 |
2048 |
| Management software included at no additional cost |
YES |
YES |
YES |
| Power & Cooling |
Standard number of power supplies |
2 |
2 |
2 |
| Power supplies are hot-swappable |
Y |
Y |
Y |
| Wattage per Controller |
400 |
420 |
480 |
| Voltage and Frequency |
100-240V 50-60Hz |
100-240V 50-60Hz |
100-240V 50-60Hz |
| E5000 Main Chassis Heat Dissipation (BTU per hour) |
2750 |
2900 |
3350 |
| Typical power consumption for 60 drives |
N/A |
1275 |
1325 |
| AutoMAID® power savings |
N |
Y |
Y |
| Size, Weight and Operating Conditions |
Operating Temperature |
10-35C (50-95F) |
10-35C (50-95F) |
10-35C (50-95F) |
| Operating Humidity |
20-95% Non Condensing |
20-95% Non Condensing |
20-95% Non Condensing |
| E5000 Main Chassis Height (U of rack space) |
5.2 in / 13.2 cm (3U) |
5.2 in / 13.2 cm (3U) |
5.2 in / 13.2 cm (3U)) |
| E5000 Main Chassis Width |
17.2 in / 43.7 cm |
17.2 in / 43.7 cm |
17.2 in / 43.7 cm |
| E5000 Main Chassis Depth |
24.2 in / 61.5 cm |
24.2 in / 61.5 cm |
24.2 in / 61.5 cm |
| E5000 Main Chassis Weight |
84 lbs / 38.1 Kg |
68 lbs / 30.1 Kg |
70 lbs / 31.8 Kg |